E0220
Ribs / rafters
520
mm
R
w
60
dB
Insulation between the supporting structure of covering
104
kg/m2
C
-3
dB
Calculation
≈
0.113
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0221
Ribs / rafters
600
mm
R
w
61
dB
Insulation between the supporting structure of covering
109
kg/m2
C
-3
dB
Calculation
≈
0.102
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0222
Ribs / rafters
366
mm
R
w
52
dB
Insulation between the supporting structure
76
kg/m2
C
-2
dB
Calculation
≈
0.16
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0223
Ribs / rafters
296
mm
R
w
52
dB
Insulation between the supporting structure
68
kg/m2
C
-2
dB
Calculation
≈
0.227
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0224
Ribs / rafters
406
mm
R
w
52
dB
Insulation between the supporting structure
81
kg/m2
C
-2
dB
Calculation
≈
0.139
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0225
Ribs / rafters
346
mm
R
w
52
dB
Insulation between the supporting structure
75
kg/m2
C
-2
dB
Calculation
≈
0.172
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0226
Ribs / rafters
366
mm
R
w
52
dB
Insulation between the supporting structure
77
kg/m2
C
-2
dB
Calculation
≈
0.157
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0227
Ribs / rafters
366
mm
R
w
52
dB
Insulation between the supporting structure
77
kg/m2
C
-2
dB
Calculation
≈
0.16
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0228
Ribs / rafters
386
mm
R
w
52
dB
Insulation between the supporting structure
79
kg/m2
C
-2
dB
Calculation
≈
0.147
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0229
Ribs / rafters
386
mm
R
w
52
dB
Insulation between the supporting structure
79
kg/m2
C
-2
dB
Calculation
≈
0.15
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0230
Ribs / rafters
406
mm
R
w
52
dB
Insulation between the supporting structure
82
kg/m2
C
-2
dB
Calculation
≈
0.138
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0231
Ribs / rafters
543
mm
R
w
44
dB
Insulation between and on supporting structure with covering
176
kg/m2
C
-3
dB
Calculation
≈
0.139
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0232
Ribs / rafters
563
mm
R
w
48
dB
Insulation between and on supporting structure with covering
176
kg/m2
C
-3
dB
Calculation
≈
0.127
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0233
Ribs / rafters
583
mm
R
w
48
dB
Insulation between and on supporting structure with covering
178
kg/m2
C
-3
dB
Calculation
≈
0.119
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0234
Ribs / rafters
603
mm
R
w
48
dB
Insulation between and on supporting structure with covering
178
kg/m2
C
-3
dB
Calculation
≈
0.11
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0235
Ribs / rafters
623
mm
R
w
48
dB
Insulation between and on supporting structure with covering
180
kg/m2
C
-3
dB
Calculation
≈
0.103
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0236
Ribs / rafters
703
mm
R
w
48
dB
Insulation between and on supporting structure with covering
184
kg/m2
C
-3
dB
Calculation
≈
0.082
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF