A0082
Hollow box element
350
mm
R
w
71
dB
L
nw
45
dB
with floor construction
227
kg/m2
C
-2
dB
C
I
-2
dB
Measurement
≈
0.306
W/m2 K
C
50-3150
-8
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2709
Solid timber, derived wood products
186
mm
R
w
43
dB
L
nw
82
dB
with floor construction
117
kg/m2
C
-1
dB
C
I
-5
dB
Measurement
≈
0.342
W/m2 K
C
50-3150
-1
dB
C
I50-2500
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2710
Solid timber, derived wood products
366
mm
R
w
65
dB
L
nw
55
dB
with floor construction
400
kg/m2
C
-1
dB
C
I
-3
dB
Measurement
≈
0.282
W/m2 K
C
50-3150
-4
dB
C
I50-2500
-1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2711
Solid timber, derived wood products
381
mm
R
w
68
dB
L
nw
46
dB
with floor construction
400
kg/m2
C
-2
dB
C
I
-2
dB
Measurement
≈
0.245
W/m2 K
C
50-3150
-3
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2712
Solid timber, derived wood products
351
mm
R
w
69
dB
L
nw
47
dB
with floor construction
376
kg/m2
C
-1
dB
C
I
-3
dB
Measurement
≈
0.254
W/m2 K
C
50-3150
-3
dB
C
I50-2500
0
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2714
Solid timber, derived wood products
326
mm
R
w
72
dB
L
nw
48
dB
with floor construction
331
kg/m2
C
-2
dB
C
I
-2
dB
Measurement
≈
0.29
W/m2 K
C
50-3150
-9
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2715
Solid timber, derived wood products
341
mm
R
w
73
dB
L
nw
43
dB
with floor construction
334
kg/m2
C
-2
dB
C
I
-1
dB
Measurement
≈
0.254
W/m2 K
C
50-3150
-6
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2716
Solid timber, derived wood products
324
mm
R
w
70
dB
L
nw
40
dB
with floor construction
281
kg/m2
C
-4
dB
C
I
0
dB
Measurement
≈
0.277
W/m2 K
C
50-3150
-9
dB
C
I50-2500
7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2725
Solid timber, derived wood products
215
mm
R
w
54
dB
L
nw
87
dB
with floor construction
289
kg/m2
C
-1
dB
C
I
-13
dB
Measurement
≈
0.429
W/m2 K
C
50-3150
-1
dB
C
I50-2500
-13
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2726
Solid timber, derived wood products
230
mm
R
w
53
dB
L
nw
62
dB
with floor construction
302
kg/m2
C
0
dB
C
I
-2
dB
Measurement
≈
0.405
W/m2 K
C
50-3150
0
dB
C
I50-2500
-2
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2727
Solid timber, derived wood products
305
mm
R
w
74
dB
L
nw
57
dB
with floor construction
405
kg/m2
C
-2
dB
C
I
-7
dB
Measurement
≈
0.302
W/m2 K
C
50-3150
-9
dB
C
I50-2500
-5
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2728
Solid timber, derived wood products
305
mm
R
w
77
dB
L
nw
44
dB
with floor construction
399
kg/m2
C
-1
dB
C
I
-4
dB
Measurement
≈
0.279
W/m2 K
C
50-3150
-6
dB
C
I50-2500
-1
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2729
Solid timber, derived wood products
264
mm
R
w
66
dB
L
nw
46
dB
with floor construction
337
kg/m2
C
-2
dB
C
I
1
dB
Measurement
≈
0.343
W/m2 K
C
50-3150
-3
dB
C
I50-2500
3
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2730
Solid timber, derived wood products
223
mm
R
w
–
L
nw
48
dB
with floor construction
291
kg/m2
C
–
C
I
1
dB
Measurement
≈
0.409
W/m2 K
C
50-3150
–
C
I50-2500
1
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2731
Ribs / joists
376
mm
R
w
70
dB
L
nw
45
dB
with dampening and floor construction
277
kg/m2
C
-2
dB
C
I
-4
dB
Measurement
≈
0.353
W/m2 K
C
50-3150
–
C
I50-2500
–
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2732
Ribs / joists
332
mm
R
w
75
dB
L
nw
40
dB
with dampening and floor construction
330
kg/m2
C
-2
dB
C
I
0
dB
Measurement
≈
0.301
W/m2 K
C
50-3150
-14
dB
C
I50-2500
8
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2733
Ribs / joists
314
mm
R
w
78
dB
L
nw
37
dB
with dampening and floor construction
374
kg/m2
C
-3
dB
C
I
0
dB
Measurement
≈
0.303
W/m2 K
C
50-3150
-10
dB
C
I50-2500
7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2734
Ribs / joists
299
mm
R
w
66
dB
L
nw
55
dB
with floor construction
177
kg/m2
C
-1
dB
C
I
-2
dB
Measurement
≈
0.337
W/m2 K
C
50-3150
-5
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2735
Ribs / joists
314
mm
R
w
73
dB
L
nw
45
dB
with dampening and floor construction
236
kg/m2
C
-2
dB
C
I
-2
dB
Measurement
≈
-0.722
W/m2 K
C
50-3150
-14
dB
C
I50-2500
7
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
A2736
Ribs / joists
267
mm
R
w
69
dB
L
nw
44
dB
with floor construction
92
kg/m2
C
-3
dB
C
I
2
dB
Measurement
≈
0.369
W/m2 K
C
50-3150
-6
dB
C
I50-2500
6
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF