A2180
BRESTA Solid Timber System
335
mm
R
w
63
dB
L
nw
53
dB
with floor construction
275
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.192
W/m2 K
C
50-3150
0
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2181
BRESTA Solid Timber System
355
mm
R
w
63
dB
L
nw
53
dB
with floor construction
275
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.17
W/m2 K
C
50-3150
0
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2182
BRESTA Solid Timber System
375
mm
R
w
64
dB
L
nw
53
dB
with floor construction
276
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.153
W/m2 K
C
50-3150
0
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2183
BRESTA Solid Timber System
415
mm
R
w
64
dB
L
nw
53
dB
with floor construction
278
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.127
W/m2 K
C
50-3150
0
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2184
BRESTA Solid Timber System
455
mm
R
w
65
dB
L
nw
52
dB
with floor construction
280
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.109
W/m2 K
C
50-3150
0
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2185
BRESTA Solid Timber System
390
mm
R
w
65
dB
L
nw
51
dB
with floor construction
285
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.261
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
A2186
BRESTA Solid Timber System
390
mm
R
w
65
dB
L
nw
51
dB
with floor construction
285
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.261
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
A2187
BRESTA Solid Timber System
390
mm
R
w
65
dB
L
nw
51
dB
with floor construction
285
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.261
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
A2188
BRESTA Solid Timber System
390
mm
R
w
65
dB
L
nw
51
dB
with floor construction
285
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.261
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
A2189
BRESTA Solid Timber System
390
mm
R
w
65
dB
L
nw
51
dB
with floor construction
285
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.261
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
A2190
BRESTA Solid Timber System
305
mm
R
w
69
dB
L
nw
46
dB
with floor construction
453
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.338
W/m2 K
C
50-3150
-1
dB
C
I50-2500
2
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2191
BRESTA Solid Timber System
345
mm
R
w
70
dB
L
nw
45
dB
with floor construction
510
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.32
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2192
BRESTA Solid Timber System
385
mm
R
w
71
dB
L
nw
44
dB
with floor construction
567
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.304
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2193
BRESTA Solid Timber System
405
mm
R
w
71
dB
L
nw
44
dB
with floor construction
577
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.291
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2194
BRESTA Solid Timber System
445
mm
R
w
72
dB
L
nw
43
dB
with floor construction
634
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.277
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2195
BRESTA Solid Timber System
485
mm
R
w
74
dB
L
nw
41
dB
with floor construction
691
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.265
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2196
BRESTA Solid Timber System
505
mm
R
w
75
dB
L
nw
40
dB
with floor construction
701
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.255
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2197
BRESTA Solid Timber System
545
mm
R
w
75
dB
L
nw
39
dB
with floor construction
758
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.244
W/m2 K
C
50-3150
0
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2198
BRESTA Solid Timber System
285
mm
R
w
68
dB
L
nw
47
dB
with floor construction
424
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.348
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2199
BRESTA Solid Timber System
325
mm
R
w
69
dB
L
nw
46
dB
with floor construction
481
kg/m2
C
-2
dB
C
I
-7
dB
Calculation
≈
0.329
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF