A2100
BRESTA Solid Timber System
321
mm
R
w
56
dB
L
nw
59
dB
with floor construction
151
kg/m2
C
-5
dB
C
I
0
dB
Calculation
≈
0.298
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2101
BRESTA Solid Timber System
341
mm
R
w
56
dB
L
nw
59
dB
with floor construction
161
kg/m2
C
-5
dB
C
I
0
dB
Calculation
≈
0.285
W/m2 K
C
50-3150
-6
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2102
BRESTA Solid Timber System
361
mm
R
w
57
dB
L
nw
58
dB
with floor construction
171
kg/m2
C
-5
dB
C
I
0
dB
Calculation
≈
0.273
W/m2 K
C
50-3150
-5
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2103
BRESTA Solid Timber System
201
mm
R
w
52
dB
L
nw
63
dB
with floor construction
138
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.401
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2104
BRESTA Solid Timber System
221
mm
R
w
53
dB
L
nw
62
dB
with floor construction
147
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.378
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2105
BRESTA Solid Timber System
241
mm
R
w
54
dB
L
nw
61
dB
with floor construction
157
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.357
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2106
BRESTA Solid Timber System
261
mm
R
w
54
dB
L
nw
61
dB
with floor construction
167
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.339
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2107
BRESTA Solid Timber System
281
mm
R
w
55
dB
L
nw
60
dB
with floor construction
177
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.322
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2108
BRESTA Solid Timber System
301
mm
R
w
55
dB
L
nw
60
dB
with floor construction
187
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.307
W/m2 K
C
50-3150
-1
dB
C
I50-2500
1
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2109
BRESTA Solid Timber System
321
mm
R
w
56
dB
L
nw
59
dB
with floor construction
196
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.293
W/m2 K
C
50-3150
-1
dB
C
I50-2500
2
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2110
BRESTA Solid Timber System
341
mm
R
w
56
dB
L
nw
59
dB
with floor construction
206
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.28
W/m2 K
C
50-3150
-1
dB
C
I50-2500
2
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2111
BRESTA Solid Timber System
361
mm
R
w
56
dB
L
nw
59
dB
with floor construction
216
kg/m2
C
-2
dB
C
I
0
dB
Calculation
≈
0.269
W/m2 K
C
50-3150
-1
dB
C
I50-2500
2
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2112
BRESTA Solid Timber System
309
mm
R
w
64
dB
L
nw
51
dB
with floor construction
147
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.392
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2113
BRESTA Solid Timber System
329
mm
R
w
65
dB
L
nw
50
dB
with floor construction
157
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.37
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2114
BRESTA Solid Timber System
349
mm
R
w
66
dB
L
nw
49
dB
with floor construction
166
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.35
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2115
BRESTA Solid Timber System
369
mm
R
w
66
dB
L
nw
49
dB
with floor construction
176
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.332
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2116
BRESTA Solid Timber System
389
mm
R
w
67
dB
L
nw
48
dB
with floor construction
186
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.316
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2117
BRESTA Solid Timber System
409
mm
R
w
67
dB
L
nw
48
dB
with floor construction
196
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.301
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2118
BRESTA Solid Timber System
429
mm
R
w
68
dB
L
nw
47
dB
with floor construction
206
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.288
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX
A2119
BRESTA Solid Timber System
449
mm
R
w
68
dB
L
nw
47
dB
with floor construction
215
kg/m2
C
-4
dB
C
I
1
dB
Calculation
≈
0.276
W/m2 K
C
50-3150
-1
dB
C
I50-2500
10
dB
Detail
IFC4 LOD300
XLSX